By the Scott Niehaus Air Conditioning & Heating team · Updated October 6, 2026
A compressor that won't start is often called locked. Sometimes it is mechanically stuck or fighting a weak capacitor, and a start-assist kit gives it the extra push to start. If the motor windings have failed, it can't be saved and a replacement is the honest answer.
The short answer
- A locked compressor hums, trips its overload, and won't run.
- A start-assist (hard start) kit adds a burst of starting torque.
- It can save a compressor that is stuck or struggling, not one with failed windings.
- Testing tells the difference before anyone quotes a new system.
What does a locked compressor look like from the house?
The outdoor fan may spin or stop, the unit hums or clicks, and the air inside stops getting cold. The compressor tries to start, draws heavy current, and its internal thermal overload shuts it off to protect it.
What is a start-assist kit?
A small add-on that gives the compressor a short burst of extra starting torque, then drops out once the motor is running. On a compressor that is stuck or straining against high pressure at start-up, that extra push is often enough to get it running and keep it running.
How can you tell whether a compressor can be saved?
By testing, not guessing. A thorough diagnosis checks the start and run capacitors, the voltage at the unit, the current the compressor draws, and the windings themselves. Windings that are shorted or grounded mean the compressor has failed.
When is a start-assist the wrong fix?
When the windings are shorted or grounded, when the compressor has lost its refrigerant to a major leak, or when the system is old enough that the money belongs in a change-out. A start-assist on a failed compressor only delays the bill.
How Scott Niehaus AC handles this
- A homeowner was told their compressor was locked up and needed a $10,000 whole-system replacement. Scott inspected the system, unlocked the compressor, installed a start-assist kit, and the original system is still running today.
Common questions
Can a locked compressor be fixed?
Sometimes. If it is mechanically stuck or struggling to start, a start-assist kit can get it running. If the windings have failed, the compressor or the system needs replacing.